Jestheticmed
Professional Electrolysis Hair Removal Machine — Blend, Thermolysis & Galvanic | JM-EL1
Professional Electrolysis Hair Removal Machine — Blend, Thermolysis & Galvanic | JM-EL1
Couldn't load pickup availability
JM-EL1
Precision Electrolysis
System
Galvanic, Thermolysis and Blend in one desktop console — the only modality that treats white, grey, blonde and red hair, on every skin tone, permanently.
DC · RF · Blend
zones on-screen
to dermal papilla
coagulation point
skin types
Why the JM-EL1 earns its
place in the treatment room
Blend mode — chemical and thermal destruction in a single insertion
Three selectable modalities from one console
Independent of hair colour and skin tone
Guided touchscreen — gender selection and 10 zones each
Foot-pedal actuation with a fixed exposure per press
Single-use sterile probes, matched to hair calibre
Specifications & operating parameters
| System | |
|---|---|
| Modality | Needle electrolysis — Galvanic (DC), Thermolysis (RF / high frequency), Blend (DC + RF simultaneous) |
| Application | Permanent hair removal, all hair colours, Fitzpatrick I–VI |
| Interface | Colour capacitive touchscreen; gender selection followed by 10 anatomical zones per gender |
| Actuation | Foot pedal; one fixed pre-set exposure per press |
| Session counters | Total runtime since power-on; total work cycles (pedal actuations) |
| Self-check | Automatic module self-test on power-up with on-screen error reporting |
| Form factor | Desktop console, angled screen, integrated probe holder |
| Power supply | Mains, three-conductor cord with protective earth — an earthed socket is required |
| Treatment parameter | Reference value |
|---|---|
| Thermolysis — exposure | 0.258 s (factory reference) |
| Blend — exposure | 0.2 s (factory reference) |
| Energy level | 45% (factory reference), adjustable on screen |
| Follicular target temperature | 48–50 °C — rapid protein coagulation |
| Insertion angle | 30–45°, along the direction of hair growth |
| Insertion depth | 2–4 mm, to the dermal papilla |
| Probe | Single-use, individually sterile-packed; diameter selected to hair calibre |
| Treatment interval | 8–10 weeks between sessions on the same area |
Treatment protocol
Consultation and assessment
Review medical history, allergies and current medication, and exclude the contraindications listed below. Assess hair colour, thickness and density with skin type, then build the treatment plan. Explain session duration, sensation and expected skin reaction, and take written informed consent.
Preparation
Cleanse with an alcohol-free antibacterial cleanser to remove sebum and cosmetic residue. Hair must not be plucked, waxed or epilated beforehand — the follicle has to be present. Topical anaesthetic may be applied around 30 minutes ahead where site and tolerance warrant it.
Device set-up
Power on and confirm the self-check completes without error. Select gender and zone, choose the modality, and set energy and exposure from the reference values. Open a fresh sterile probe in front of the client and fit the diameter matched to the hair.
Insertion
Insert slowly at 30–45° along the growth direction, to 2–4 mm, until the probe reaches the dermal papilla. The insertion should meet no resistance; surrounding tissue must not be pierced.
Delivery and verification
Actuate via the foot pedal and observe the client's expression and the skin throughout. Release at the end of the pre-set duration, then lift the hair with sterile forceps. Effortless, painless release confirms the follicle has been destroyed; resistance means re-treatment, not traction.
Absolute
- Cardiac pacemakers and other implanted electronic devices
- History of epilepsy or seizure disorder
- Known allergy to metals used in the probe
- Pregnancy and lactation
Defer or refer
- Acute infection, or active herpes at or near the site
- Coagulation disorders, or current anticoagulant therapy
- Broken, inflamed or recently treated skin in the area
- Any case where medical clearance has not been obtained
| First 24 h | Keep clean and dry; no water contact, bathing or swimming |
| 24–48 h | Cool compresses for mild erythema or swelling; bland soothing gel, lotion or cream as needed |
| Avoid | Cosmetics, perfume and alcohol-containing moisturisers on the area; friction from tight clothing |
| Sun | SPF 30+ / PA+++ plus hats or physical cover; avoid direct exposure for several weeks |
| Normal reaction | Mild redness and small crusts; crusts must not be picked or removed |
| Escalate | Marked swelling or any purulent discharge — refer to the treating clinician immediately |
| Next session | 8–10 weeks for the same area |
Supplied through
Jestheticmed
We source professional aesthetic systems directly from manufacture and supply clinics, medspas and distributors across the UK, EU, North America and Australia — with the documentation, training material and parts support that a device needs after the pallet is signed for.
| Ordering | |
|---|---|
| Model | JM-EL1 Precision Electrolysis System |
| Supplied with | Console · probe handpiece and lead · foot pedal · earthed mains cord · starter set of sterile single-use probes · English manual |
| Consumables | Single-use sterile probes, supplied by diameter — resupply available per box |
| Branding | OEM and private-label options available on volume orders |
| Lead time | Confirmed at order against current production schedule |
| Also available from Jestheticmed | |
|---|---|
| JM-808 TRIO | 755 / 808 / 1064 nm diode laser hair removal platform |
| JM-ICE2 | Cryo-HIFU — Single-Point ICE Vmax and Multi-Row ICE HIFU12 |
| JM-M8 Crystallite | Insulated gold-plated RF microneedling, 0.5–7 mm programmable depth |
| JM-1550 | Non-ablative fractional laser resurfacing |
jestheticmed.com
Colorado, United States
Australia · Middle East